卷帘门控制箱是整个防火卷帘门的技术核心部分,影响整个防火联动系统。在此,我们将介绍防火卷帘门控制箱的接线注意事项:请参阅接线盒的接线图,了解每个端子的功能和接线要求,然后正确进行接线有线。
Rolling shutter door control box is the core part of the whole fireproof rolling shutter door technology, which affects the whole fireproof linkage system. Here, we will introduce the wiring precautions of the fire shutter door control box: first, please refer to the wiring diagram of the junction box to understand the function and wiring requirements of each terminal, and then conduct the wiring correctly.
确认接线正确后,使用500V兆欧表或振动器测试绝缘电阻;要求将电源接线子电动机的接线端子连接到机箱上,且相互绝缘电阻值不小于300MΩ;如果绝缘电阻符合要求,则可以进行电源调试工作。打开电源,检查"正常"指示灯是否点亮。
After confirming that the wiring is correct, use a 500V megohmmeter or vibrator to test the insulation resistance; it is required to connect the terminals of the power connector motor to the chassis, and the mutual insulation resistance value is not less than 300m Ω; if the insulation resistance meets the requirements, the power debugging can be carried out. Turn on the power and check whether the "normal" indicator is on.

如果它没有点亮(控制回路已死),则应更改电源线中的任何两相;否则,请更改电源线。手动控制卷门的上,下,停止和限制开关。调整在无火的情况下,按下"向上"按钮,卷帘门应下降;按下"停止"按钮,滚动门应停止运行。
If it does not light up (the control loop is dead), change any two phases in the power cord; otherwise, change the power cord. Manually control the up, down, stop and limit switches of the rolling door. In the case of no fire, press the "up" button, the rolling door should fall; press the "stop" button, the rolling door should stop running.
在测试运行期间,顶部和底部之间可能会有差异。在这种情况下,您只需要更改两个葫芦的三相接线。然后尝试确定与运行方向相对应的限位是否有效(用手触摸微动开关),当该功能不起作用时,应更换限位线;然后调整行程开关的位置以打开和关闭防火百叶窗门。
There may be differences between the top and bottom during the test run. In this case, you only need to change the three-phase wiring of the two hoists. Then try to determine whether the position corresponding to the direction of operation is effective (touching the micro switch by hand). When the function does not work, the limit line should be replaced; then the position of the travel switch is adjusted to open and close the fire shutter door.
阅读/ Recommended reading
- 济南卷帘门:装修完工也能装!水晶卷帘门微创加装,吊顶无损不返工 2026-03-26
- 带防砸神器的济南卷帘门:一碰即停!告别砸车伤人,灵敏度远超行业标准 2026-03-25
- 济南卷帘门降噪秘诀:别再换门!一招加粗转轴,噪音直降70%,耐用翻倍 2026-03-24
- 济南业主疯换!双铝电动卷帘门,省空间不生锈,手动款彻底淘汰 2026-03-23
- 济南卷帘门厂家教你:门体下降卡住应急处理,3步化解无风险 2026-03-19
- 手动卷帘门推拉失灵?多是轴体隐性断裂,保养不到位才是根源 2026-03-12
- 手动卷帘门推拉失灵?多是轴体隐性断裂,保养不到位才是根源 2026-04-07
- 济南防火卷帘门安装三个问题点需要注意 2026-03-05
济南卷帘门厂家科普:电动卷帘门停电别慌!一招手动解锁,3秒顺畅升降
2026-03-27
济南卷帘门厂家科普:电动卷帘门停电别慌!一招 Jinan rolling shutter door manufacturer's science popularization...